<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-26 01-43-26
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 70 dBuV YLEX
Pilot RDS Phase Difference
7.3 kHz 2.2 kHz 58 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 10 kHz 19059 0,0367
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,6 dBr 1,03 dBr 3,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 1:43, 26.12.2024
RT
"Rony Rex "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6207, 6205, 6201, 6203
FM Scope Max at: 10 kHz MIN: 9 kHz % above 76 kHz: 0,0367 Acquired: 2024/12/26 1.42.22 Total samples: 19059 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 3,3 dBr MIN: 0,6 dBr AVE: 1,03 dBr % above 12,2 dBr: 0,0 Last value: 3,3 dBr (2024/12/26 1.42.21) 01.28 01.30 01.32 01.34 01.36 01.38 01.40 01.42 0 50 100 Dev. MAX [kHz] -1 0 1 2 3 4 Pm [dBr]